Безопасное электроснабжение информационных центров

Low-voltage main distribution board, feed-in

A safe power supply forms the basis for secure data

Low-voltage main distribution board

Safety, maximum availability and economic viability in server parks, data centres and IT rooms are now a MUST and require a fault-free power supply. The supplied medium voltage is transformed down to 400 V in the transformer stations and fed to the data centre via cable bars or busbars and the low-voltage main distribution board and normal system sub-distribution panel. The normal system sub-distribution panel also provides the uninterruptible power supply (UPS) with electricity. The power supply is permanently monitored by Bender AC/DC sensitive and multi-channel residual current monitoring systems. This avoids fire hazards, operational interruptions, functional problems damage and, in the worst-case scenario, data loss as a result of faulty electrical insulation or EMC influence. Bender monitoring systems protect your data every day. Possible risks are recognised early before problems arise. Power quality is the perfect solution for monitoring of low-voltage main distribution boards. Monitoring of the central earthing points via an RCMS guarantees that there is only one connection between N and PE in line with the standards. 

Обзор продукции ISOMETER®
Обзор продукции Power Quality
Флайер Power Quality
Техническая информация The future needs safety

Рекомендуемые устройства для контроля сопротивления изоляции (-онлайн / оффлайн):

Рекомендуемые средства для постоянного мониторинга:

Рекомендуемые системы для контроля дифференциального тока:

Рекомендуемые адапторы:

Оценка и отчет:

DIN VDE 0100-731
Errichten von Niederspannungsanlagen - Teil 7-731: Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Abgeschlossene elektrische Betriebsstätten

ETSI EN 301605
Environmental Engineering (EE); Earthing and bonding of 400 VDC Data and Telecom (ICT) Equipment - Erdung und Potentialausgleich von Einrichtungen der Informations- und Kommunikationstechnik mit DC 400 V in Rechenzentren und in Betriebsgebäuden der Telekommunikationstechnik (Anerkennung der Englischen Fassung EN 301 605 V1.1.1 (2013-10) als Deutsche Norm)

Sub-distribution panel, busbar systems

Interference-free and easy connection

Sub-distribution panel

The connection between the low-voltage main distribution board and the sub-distribution panels is via busbar systems in order to guarantee the supply is as fault-free as possible. Power quality and RCMS residual current monitoring systems help with this monitoring.

Обзор продукции Power Quality

Рекомендуемые системы для контроля дифференциального тока:

Рекомендуемые средства для постоянного мониторинга:

Оценка и отчет:


Generators

Emergency power systems ensure uninterrupted power supply

Generators

Electricity providers are not always able to guarantee perfect supply of electrical energies everywhere. Short interruptions or sustained power outages must be bridged by emergency power systems in order to maintain the operation of a data centre, including the associated technical systems, such as air-conditioning, electricity and security. The Bender solutions control the changeover and monitor the emergency power system for electrical faults.

Обзор продукции Residual current monitoring
Обзор продукции Power Quality
Брошюры Data centre
Техническая информация Construction of a new computer centre

Рекомендуемые устройства для контроля сопротивления изоляции (-онлайн / оффлайн):

Рекомендуемые адапторы:

Оценка и отчет:

DIN VDE 0100-731
Errichten von Niederspannungsanlagen - Teil 7-731: Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Abgeschlossene elektrische Betriebsstätten

ETSI EN 301605
Environmental Engineering (EE); Earthing and bonding of 400 VDC Data and Telecom (ICT) Equipment - Erdung und Potentialausgleich von Einrichtungen der Informations- und Kommunikationstechnik mit DC 400 V in Rechenzentren und in Betriebsgebäuden der Telekommunikationstechnik (Anerkennung der Englischen Fassung EN 301 605 V1.1.1 (2013-10) als Deutsche Norm)

UPS

Switching to emergency power without interruption

UPS

An uninterruptible power supply (UPS) is used to ensure the supply of critical electrical loads in the event of problems in the power supply. The UPS systems (normally battery or oscillating weight systems) bridge the period until the emergency power systems (generators) are activated or the system is available again. Electrical safety is continuously monitored by Bender products. 

Обзор продукции Residual current monitoring
Обзор продукции Power Quality
Брошюры Data centre
Техническая информация Bender protects high-availability building installations

Рекомендуемые устройства для контроля сопротивления изоляции (-онлайн / оффлайн):

Рекомендуемые системы для контроля дифференциального тока:

Рекомендуемое оборудование для измерения электрического тока:

Оценка и отчет:

DIN EN 50272-2
Safety requirements for secondary batteries and battery installations - Part 2: Stationary batteries